Ventilation technology (5 ECTS)
Code: TX00BT01-3011
General information
- Enrollment
- 02.12.2024 - 07.01.2025
- Registration for the implementation has ended.
- Timing
- 13.01.2025 - 18.05.2025
- Implementation has ended.
- Number of ECTS credits allocated
- 5 ECTS
- Mode of delivery
- On-campus
- Campus
- Myllypurontie 1
- Teaching languages
- Finnish
- Degree programmes
- Degree Programme in Construction Site Management
- Teachers
- Pasi Partonen
- Groups
-
TXI24S2ARakennusalan työnjohdon tutkinto-ohjelma monimuoto, LVI-tekniikan suuntautuminen
- Course
- TX00BT01
Implementation has 15 reservations. Total duration of reservations is 26 h 15 min.
Time | Topic | Location |
---|---|---|
Wed 15.01.2025 time 12:00 - 13:45 (1 h 45 min) |
Ilmastointitekniikka TX00BT01-3011 |
MPA2009
Talotekniikan opetustila
|
Wed 22.01.2025 time 12:00 - 13:45 (1 h 45 min) |
Ilmastointitekniikka TX00BT01-3011 |
MPA2009
Talotekniikan opetustila
|
Wed 29.01.2025 time 12:00 - 13:45 (1 h 45 min) |
Ilmastointitekniikka TX00BT01-3011 |
MPA2009
Talotekniikan opetustila
|
Wed 05.02.2025 time 12:00 - 13:45 (1 h 45 min) |
Ilmastointitekniikka TX00BT01-3011 |
MPA2009
Talotekniikan opetustila
|
Wed 12.02.2025 time 12:00 - 13:45 (1 h 45 min) |
Ilmastointitekniikka TX00BT01-3011 |
MPA2009
Talotekniikan opetustila
|
Wed 26.02.2025 time 12:00 - 13:45 (1 h 45 min) |
Ilmastointitekniikka TX00BT01-3011 |
MPA2009
Talotekniikan opetustila
|
Wed 05.03.2025 time 12:00 - 13:45 (1 h 45 min) |
Ilmastointitekniikka TX00BT01-3011 |
MPA2009
Talotekniikan opetustila
|
Wed 12.03.2025 time 12:00 - 13:45 (1 h 45 min) |
Ilmastointitekniikka TX00BT01-3011 |
MPA2009
Talotekniikan opetustila
|
Wed 19.03.2025 time 12:00 - 13:45 (1 h 45 min) |
Ilmastointitekniikka TX00BT01-3011 |
MPA2009
Talotekniikan opetustila
|
Wed 26.03.2025 time 12:00 - 13:45 (1 h 45 min) |
Ilmastointitekniikka TX00BT01-3011 |
MPA2009
Talotekniikan opetustila
|
Wed 02.04.2025 time 12:00 - 13:45 (1 h 45 min) |
Ilmastointitekniikka TX00BT01-3011 |
MPA2009
Talotekniikan opetustila
|
Wed 09.04.2025 time 12:00 - 13:45 (1 h 45 min) |
Ilmastointitekniikka TX00BT01-3011 |
MPA2009
Talotekniikan opetustila
|
Wed 16.04.2025 time 12:00 - 13:45 (1 h 45 min) |
Ilmastointitekniikka TX00BT01-3011 |
MPA2009
Talotekniikan opetustila
|
Wed 23.04.2025 time 12:00 - 13:45 (1 h 45 min) |
Ilmastointitekniikka TX00BT01-3011 |
MPA2009
Talotekniikan opetustila
|
Wed 30.04.2025 time 12:00 - 13:45 (1 h 45 min) |
TENTTI Ilmastointitekniikka TX00BT01-3011 |
MPA3010
Digitila
|
Learning outcomes
On completion of the course the student has an overall understanding of the factors influencing indoor climate, ways of controlling them, ventilation systems and their role in the construction project.
The student will be familiar with air conditioning systems for residential buildings and public spaces, the basic processes of handling air flow, the concepts and definitions of ventilation and air conditioning, and also the rules and regulations, instructions and standards governing ventilation systems and equipment.
The student has the necessary skills to design the ventilation system of a single-family house.
Content
Indoor climate factors and quality classification
Factors influencing the indoor climate and the related quality classifications
Rules, regulations and standards governing ventilation
Ventilation systems for residential buildings
Air-conditioning systems for offices and public spaces
Calculating the cooling load of an office room
Basic processes of air conditioning in an H-x diagram
Ventilation duct system, its components and design
Energy efficiency and noise
Air distribution and air distribution equipment
Fire safety and the purity of indoor air
Prerequisites
Systems and Product Information
Teaching methods
Lähiluennot (Lähitoteutuksella opetukseen osallistutaan, luentoja ei voi seurata etänä)
Location and time
Lähiopetus lukujärjestyksessä
Learning materials and recommended literature
Opintojakson kaikki materiaali ja kirjallisuus Moodlessa
Alternative completion methods of implementation
Ei valinnaisia suoritustapoja
Internship and working life connections
Ei
Exam dates and retake possibilities
Tenttien ajankohdat julkaistaan ensimmäisellä opetuskerralla
International connections
Ei
Student workload
5 op (5*27h=135h opiskelija työtä)
Content scheduling
Käydään läpi opintojakson alussa
Further information for students
Opiskelija selvittää muilta opiskelijoilta opetuksen toteuttamiseen liittyvät asiat ollessaan poissa toteutuksen tunneilta
Assessment methods and criteria
Arviointi tentin perusteella
Evaluation scale
0-5
Assessment criteria, satisfactory (1)
The student can determine the optimal air flow in the ventilation system of a single family house, and select the ventilation device, duct sizes and terminal devices.
The student can describe the main requirements of a single-family house ventilation system.
The student can to explain the concepts of humidity and enthalpy, and to define the dew point.
Assessment criteria, good (3)
In addition to the requirements listed above, the student can make an overall plan of the ventilation system for a single-family house, including noise reduction solutions and insulation.
The student can explain the factors affecting the cooling load of an office room and the principles of air-conditioning in office buildings.
The student can perform basic calculations related to sound engineering.
The student can determine the basic processes of air conditioning using an h-x diagram.
Assessment criteria, excellent (5)
In addition to the requirements listed above, the student can compare different solutions from the point of view of energy consumption, smooth operation and maintenance, and can independently plan the ventilation system of a single-family house.
Assessment criteria, approved/failed
The student can determine the optimal air flow in the ventilation system of a single family house, and select the ventilation device, duct sizes and terminal devices.
The student can describe the main requirements of a single-family house ventilation system.
The student can to explain the concepts of humidity and enthalpy, and to define the dew point.